新闻中心
Home > News Center > Company News

Standardized Process for Oil Rig Brake Pad Maintenance
2025-09-22 20:05:07

Standardized Process for Oil Rig Brake Pad Maintenance


Preventive Maintenance System

A three-tier maintenance system is recommended based on API RP 54:


Daily Inspection: Measure remaining thickness at each shift change (vernier caliper accuracy 0.02mm)


Monthly Maintenance: Clean friction surfaces and check spring preload


Annual Overhaul: Complete replacement and brake performance test


Typical Troubleshooting Solutions


Abnormal Vibration: Prioritize checking for eccentric brake pad wear


Braking Delay: Check for hydraulic oil contamination or friction coefficient degradation


Abnormal Noise: Often indicates delamination of the friction material